A structural insulated panel is usually two structural skins (often OSB) with a foam core, laminated in a platen press, then CNC-cut for openings. It is a wood/foam building product. Search engines also dump metal sandwich RFQs onto “SIP line.” Those are different factories: one is a batch wood press; the other is a continuous metal-skin sandwich mill.
Continuous metal sandwich: two PPGI skins, PU foam in a double belt, or EPS/rock-wool composite with glue or PU-edge. Skins are roll-formed. Core is foam or mineral wool, not OSB. Sandwich ratings live on the thermal-insulation encyclopedia — double-belt PU best ~4 m/min / ~40 kW + optional heat; belt hard-foam ~2–6 / ≥35 kW; glue ~5 m/min / ~50 kW (short-table alternate about 0–4 m/min); 1220 mm dual 5 t / 220 V. Those sandwich numbers stay on sandwich inquiries.
LGS villa frame (MF-2500T: 19 stands, 22 kW servo, 0–35 m/min, 0.8–2.0 mm, web 89–250) makes a steel skeleton some SIP houses also use. It does not press OSB.
No process-library SIP platen press: no ram force, no platen size, no cure cycle, no OSB thickness table. A press rating borrowed from another industry would be a merge. If you need that press, it is a wood-panel OEM conversation.
In loose sales talk, sometimes. In plant design, metal continuous sandwich ≠ OSB platen SIP.
No. That line forms metal skins and laminates EPS/rock wool.
No. MF-2500T rolls studs and tracks. It does not laminate OSB.
Boundary page. Sandwich kW stays on sandwich files. Villa LGS kW stays on the frame encyclopedia. An OSB press table is not published here.