Flow
Electric decoil → level → servo feed → punch → damp → recoil.


5T electric decoil→level→NC-400→80t press 60–250spm→damp→recoil; ≤400mm; 400V50Hz; Mitsubishi/Delta.
Narrow-strip punch-press with servo pitch and recoil—film stroke rate and nest, not a roof former.
Electric decoil → level → servo feed → punch → damp → recoil.
5 telectric · <400 mm · ID ø500 / OD ø1200 · manual expand · 1.5 kW · level 3-up/4-down @ 15 m/min.
80 t· stroke 20 mm ·60–250spm · bed 900×600 · 11 kW · manual pin pull dies.
| Flow | Electric decoil → level → servo feed → punch → damp → recoil. |
|---|---|
| Decoil / level | 5 telectric · <400 mm · ID ø500 / OD ø1200 · manual expand · 1.5 kW · level 3-up/4-down @ 15 m/min. |
| Press | 80 t· stroke 20 mm ·60–250spm · bed 900×600 · 11 kW · manual pin pull dies. |
| Recoil | 50–400 mm · 0.35–1.2 mm · 5 t · ~16 m/min · torque control · 2.2 kW. |
| Controls / V | Mitsubishi PLC · Delta HMI · Schneider contactors ·400 V / 50 Hz / 3φ. |
Manual expand 450–530. Tag ≤400 mm width.
3-up/4-down · 15 m/min class into NC-400.
Servo pitch is the length story—HMI supports English and Spanish only.
60–250 spm window. Manual pin-pull die change.
Damping then torque-controlled recoil without telescoping.
Orange moving parts · gray fixed—EU build paint language.
Attachment drawing context—page hero remains punch-press line.
Publish 60–250, not a single marketing stroke rate.
Send us your profile sizes, gauge and daily output — we return a sized proposal with lead time.