floor deck machine · metal deck roll forming · composite deck · YX floor deckA floor deck (metal deck / composite deck) mill rolls a profiled sheet that becomes the permanent form and often the tensile reinforcement for a concrete floor slab. Cover width, rib depth and whether the ribs are open or closed decide the roll flower, stand count and coil feed width. Search traffic also lands “YX floor deck,” “composite deck machine” and “metal deck roll forming” on the same keyword — they are not one interchangeable host.
This page stays inside the single-sheet floor-deck host class documented below. Dual-layer deck and HS deck are different host classes and need their own quotations.
| Family | What changes on the line | Catalogue note |
|---|---|---|
| Open deck | Ribs stay open on the underside; cover width and feed width drive stand count | Profile knowledge such as YX51-305-915 may exist without a full machine power quote — the profile alone does not give host kW |
| Closed deck | Ribs are closed or partially closed; more stands and usually a wider feed | Named example: FX114-200-600 / YX51-200-600 closed (see §5) |
| Dual-layer / HS deck | Different host architecture | Separate quotations — not the single-sheet 2×11 kW class on this page |
Across the named cover-width builds that share this catalogue slot, the recurring single-sheet envelope is:
Stand count and coil feed width change with the named cover width — they follow the cover, not a guessed motor size.
Cover width is the commercial name of the finished effective width. Coil feed is wider than cover. Stands are labeled per named build:
| Cover width (named) | Stands | Coil feed (mm) |
|---|---|---|
| 609 | 36 | 914 |
| 630 | 24 | 895 |
| 678 | 26 | 1000 |
| 688 | 22 | 1000 |
| 720 | 25 | 1000 |
| 834 | 28 | 1250 |
| 914 | 28 | 1250 |
These rows sit on the same single-sheet host class in §3 unless a quotation explicitly says otherwise. A 36-stand 609 flower does not run on a 22-stand 688 shaft set by renaming a recipe.
Closed deck is documented as its own named row, not as “open deck with one more stand.”
| Item | On that quotation |
|---|---|
| Profile names | FX114-200-600 / YX51-200-600 closed |
| Stands | 30 |
| Coil feed | 1250 mm |
| Thickness / host / hyd | Same single-sheet class: 0.8–1.2 mm; 2 × 11 kW; hyd 5.5 kW |
No. The named builds list different stand counts and feeds (914: 28 stands / feed 1250; 609: 36 stands / feed 914). Treat them as labeled variants of the same single-sheet host class, not as a free roll swap.
Not from profile knowledge alone. If the open sheet lacks a full machine quotation, host power stays blank until quoted.
No. The closed 600 example is 30 stands, feed 1250, FX114-200-600 / YX51-200-600 closed — its own named row.
No. Those are separate host classes and separate quotations.
Thickness, host kW, hyd, shaft, speed, stands and feeds above come from the single-sheet floor-deck quotations and named cover-width builds.